BRGBG - ECCOSPRAY 122S

  • MSDS: BRGBG
  • Manufacturer: EMERSON AND CUMING INC
  • Product Name: ECCOSPRAY 122S
  • National Stock Number: 8030-00N038717
Product Identification

Product ID:ECCOSPRAY 122S
MSDS Date:11/13/1990
FSC:8030
NIIN:00N038717
MSDS Number: BRGBG

Responsible Party
EMERSON & CUMING INC
77 DRAGON CT
WOBURN, MA 01888
US

Emergency Phone: 617-935-4850;617-938-8630

Info Phone: 617-828-3300

Cage: DO244

Contractor
EMERSON & CUMING INC DIV/W R GRACE CO
AUOBURN, MA 01888 US

Telephone: (617) 935-4850 OR (617) 938-8630

Cage: DO244

Ingredients

METHANE, DICHLORO-; (METHYLENE CHLORIDE)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 50-60%

OSHA PEL 500 PPM; 1000, C

ACGIH TLV: 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


METHANE, DICHLORODIFLUORO-; (FREON 12)

CAS: 75-71-8

RTECS: PA8200000

Fraction By Weight: 30-45%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


SILICONE RESIN

Fraction By Weight: <5%


& COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS

RTECS: 9999999ZZ


LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY

RTECS: 9999999ZZ


INTO CONTRS. SCRUB AREA W/SOAPY WATER & RINSE.

RTECS: 9999999ZZ


CONC TO PREVENT LOCAL BUILDUP OF VAPOR.

RTECS: 9999999ZZ


CHLORIDES, FLUORIDES .

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: VAPS MAY CAUSE IRRIT TO
RESP TRACT, & MAY EXERT NARC/ANESTH EFTS. MAY BE FATAL IF
CONCENTRATED VAP ARE INHALED DIRECTLY FROM AEROSOL CONTR. EYE: SEV
IRRIT UPON DIRECT CONT. SKIN: IRRIT U PON DIRECT CONT. PRLNGD EXPOS
MAY RSLT IN DEFAT DERM. INGEST: HARMFUL IF SWALLOWED. CHRONIC:
SEVERAL (EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: GP2B(IARC), IARC
MNGRPH VOL SUP 7M P 194, 1987 ANTIC TO BE A CARCIN(NTP 6TH ANN RPT
(SUM), 199133333
Effects of Overexposure:HLTH HAZ:CHRONIC INHAL STUDIES RPTD BY NIOSH
REVEALED THAT TEST ANIMALS EXPOSED TO METHYLENE CHLORIDE CONC AS
HIGH AS 10,000 PPM SHOWED SLIGHT LIVER & KIDNEY CHANGES. WHEN
ADMINSTERED VIA INHAL TO ANI MALS IN LAB TESTS, METHYLENE CHLORIDE
OVEREXP RSLTD IN INCR INCIDENCES OF BRONCHIAL & LIVER CARCINOMAS.
(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. GIVE ARTIFICAL RESPIRATION IF NOT
BREATHING. GIVE OXYGEN IF BREATHING DIFFICULT. GET IMMEDIATELY
MEDICAL ATTENTION. EYE: IMMEDIATELY FLUSH W/WATER FOR @ LST 15 MIN;
GET MED ICAL ATTENTION. SKIN: 'EMOVE CONTAMINATED CLOTHING. WASH
AFFECTED AREA WITH SOAP AND WATER. INGEST: DILUTE WITH LARGE QTY OF
WATER. GET IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Flash Point:NON-FLAMMABLE
Extinguishing Media:WATER FOG.
Fire Fighting Procedures:NIOSH/MSHA APPRVD PRESS DEMAND SCBA & FULL
PROT EQUIP. IF LARGE QTY OF MATERIAL ARE INVOLVED, EVACUATE AREA
AND FIGHT FIRE FROM A SAFE DISTANCE.
Unusual Fire/Explosion Hazard:TOX VAPS MAY BE EVOLVED UPON EXPOS TO
HEAT/OPEN FLAME. EXPOS TO HEAT MAY RSLT IN EXPLOS RUPTURING OF
SCALED AEROSOL CONTRS. THERMAL DECOMP PROD MAY (SUPP DATA)

Accidental Release

Spill Release Procedures:FOR SM SPILLS: IF AEROSOL CANS ARE PUNCTURED,
TURN ON ALL VENT EQUIP TO EVAC VAPS. EVAC IMMED AREA WHILE
PROPELLANT & SOLV IS ALLOWED TO EVAP. ABSORB RESIDUAL MATL W/SAND,
VERMICULITE/OTHER ABSORB MAT . SCRAPE/SHOVEL ABSORBED WASTE &
ABSORB(ING 6)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY PLACE; KEEP REMOVED
FROM ANY HEAT OR OPEN FLAME. KEEP AWAY FROM HEAT, SPARKS, OPEN
FLAME.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES/HOT SURFACES. HEAT &/OR UV
RADIATION MAY CAUSE FORMATION OF CHLORIDES, FLUORIDES, AND/OR
PHOSGENE .

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:DO NOT BREATHE VAPS. USE ONLY W/PROPER MECH EXHAUST VENT.
FLEXIBLE DUCTWORK SHOULD EXTEND TO AREAS OF HIGH (ING 7)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ:INCL CHLORIDES, FLUORIDES .EFTS OF OVEREXP: CAUTION: CNTNS
METHYLENE CHLORIDE. USE ONLY IN OPEN SPACES W/ADEQ VENT. PRLNGD
BRTHG OF HIGH CONC OF VAPS IN CONFINED SPACES MAY LEAD TO LOS S OF
CONSCIOUSNESS/ASPHY. CHLOROFLUOROCARBON MATLS HAVE PRDCD SENSIT OF
MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS (ING 4)

Chemical Properties

Boiling Pt:B.P. Text:<75F,<24C
Vapor Pres:>3@25C
Vapor Density:LTR/AIR
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS AEROSOL SPRAY
Percent Volatiles by Volume:>90

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, CHEMICALLY ACTIVE METAL POWDERS (ALUMINUM,
MAGNESIUM/POTASSIUM, LITHIUM). MAY REACT VIOLENTLY ON CONT.
Stability Condition to Avoid:EXPOSURE TO HEAT &/OR OPEN FLAME.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE. MAY
EMIT HIGHLY TOX ORGANOFLUORIDES & PHOSGENE UPON THERMAL DECOMP.
(ING 8)

Disposal

Waste Disposal Methods:SPILLED MATL & WAST RINSES ARE CLASSIFIED AS
CHEM WASTE, & MUST BE DISPOSED OF I/A/W LOCAL, STATE, & FED REGS.
DO NOT INCINERATE EMPTY /UNUSED CONTR-DISPOSE OF EXPIRED MATLS AS A
NONFLAMM AEROSOL I/A/ W CURRENT LOCAL, STATE, & FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.